204 research outputs found

    Narrow band photometry of selected asteroids

    Get PDF
    The CCD photometry of selected asteroids was carried out to check for possible cometary activity in them. To distinguish the asteroids with possible cometary activity from those of the main belt, each object of interest was observed in two filters; one centered on the C2 emission band at 5140A (90A bandpass) and the other centered on the nearby continuum at 4845A (65A bandpass). None of the observed asteroids appear to have any C2 emission

    Kinetic Modeling and Effect of Process Parameters on Selenium Removal Using Strong Acid Resin

    Get PDF
    Heavy metal pollution due to the contamination of Selenium above the tolerable limit in the natural environment is a challenging issue that environmental scientists face. This study is aimed at identifying ion exchange technology as a feasible solution to remove selenium ions using 001x7 resin. Parametric experiments were conducted to identify the optimal pH, sorbent dose and speed of agitation. Selenium removal efficiency of 85% was attained at pH 5.0 with 100 mg/L selenium concentration. The increase in resin dose was found to increase removal efficiency. However, metal uptake decreased. The experiments on the effect of concentration proved the negative effect of higher concentrations of selenium on removal efficiency. The ion exchange process was proved to be optimal at an agitation speed of 200 rpm and a temperature of 35 °C. Pseudo second order model was found to fit the kinetic data very well compared to the pseudo-first order model and the pseudo second order rate constant was estimated as 8.725x10-5 g mg-1 min-1 with a solution containing 100 mg/L selenium

    Real-Time, Non-Intrusive Detection of Liquid Nitrogen in Liquid Oxygen at High Pressure and High Flow

    Get PDF
    An integrated fiber-optic Raman sensor has been designed for real-time, nonintrusive detection of liquid nitrogen in liquid oxygen (LOX) at high pressures and high flow rates in order to monitor the quality of LOX used during rocket engine ground testing. The integrated sensor employs a high-power (3-W) Melles Griot diode-pumped, solid-state (DPSS), frequency-doubled Nd:YAG 532- nm laser; a modified Raman probe that has built-in Raman signal filter optics; two high-resolution spectrometers; and photomultiplier tubes (PMTs) with selected bandpass filters to collect both N2 and O2 Raman signals. The PMT detection units are interfaced with National Instruments Lab- VIEW for fast data acquisition. Studies of sensor performance with different detection systems (i.e., spectrometer and PMT) were carried out. The concentration ratio of N2 and O2 can be inferred by comparing the intensities of the N2 and O2 Raman signals. The final system was fabricated to measure N2 and O2 gas mixtures as well as mixtures of liquid N2 and LO

    Fiber Optic Raman Sensor to Monitor Concentration Ratio of Nitrogen and Oxygen in a Cryogenic Mixture

    Get PDF
    A spontaneous Raman scattering optical fiber sensor is developed for a specific need of NASA/SSC for long-term detection and monitoring of the quality of liquid oxygen (LOX) in the delivery line during ground testing of rocket engines. The sensor performance was tested in the laboratory and with different excitation light sources. To evaluate the sensor performance with different excitation light sources for the LOX quality application, we have used the various mixtures of liquid oxygen and liquid nitrogen as samples. The study of the sensor performance shows that this sensor offers a great deal of flexibility and provides a cost effective solution for the application. However, an improved system response time is needed for the real-time, quantitative monitoring of the quality of cryogenic fluids in harsh environment

    CNS activity of Pokeweed Anti-viral Protein (PAP) in mice infected with Lymphocytic Choriomeningitis Virus (LCMV)

    Get PDF
    BACKGROUND: Others and we have previously described the potent in vivo and in vitro activity of the broad-spectrum antiviral agent PAP (Pokeweed antiviral protein) against a wide range of viruses. The purpose of the present study was to further elucidate the anti-viral spectrum of PAP by examining its effects on the survival of mice challenged with lymphocytic choriomeningitis virus (LCMV). METHODS: We examined the therapeutic effect of PAP in CBA mice inoculated with intracerebral injections of the WE54 strain of LCMV at a 1000 PFU dose level that is lethal to 100% of mice within 7–9 days. Mice were treated either with vehicle or PAP administered intraperitoneally 24 hours prior to, 1 hour prior to and 24 hours, 48 hours 72 hours and 96 hours after virus inoculation. RESULTS: PAP exhibits significant in vivo anti- LCMV activity in mice challenged intracerebrally with an otherwise invariably fatal dose of LCMV. At non-toxic dose levels, PAP significantly prolonged survival in the absence of the majority of disease-associated symptoms. The median survival time of PAP-treated mice was >21 days as opposed to 7 days median survival for the control (p = 0.0069). CONCLUSION: Our results presented herein provide unprecedented experimental evidence that PAP exhibits antiviral activity in the CNS of LCMV-infected mice

    Some further measurements of Uranian ring condensations

    Get PDF
    The results of photometric observations of the occultation of BD-19° 4222 by Uranus on April 26, 1981 from two stations in India conform with the model proposed by Elliotet al. (1981)

    Time-Series Photometry of M67: W UMa Systems, Blue Stragglers, and Related Systems

    Get PDF
    We present an analysis of over 2200 V images taken on 14 nights at the Mt. Laguna 1 m telescope of the open cluster M67. Our observations overlap but extend beyond the field analyzed by Gilliland et al. (1991), and complement data recently published by van den Berg et al. (2002) and Stassun et al. (2002). We show variability in the light curves of all 4 of the known W UMa variables on timescales ranging from a day to decades (for AH Cnc). We have modeled the light curve of AH Cnc, and the total eclipses allow us to determine q = 0.16 +0.03/-0.02 and i = 86 +4/-8 degrees. The position of this system near the turnoff of M67 makes it useful for constraining the turnoff mass for the cluster. We have also detected two unusual features in the light curve of AH Cnc that may be caused by prominences. We have also monitored cluster blue stragglers for variability, and we present evidence hinting at low level variations in the stragglers S752, S968, and S1263, and we place limits on the variability of a number of other cluster blue stragglers. Finally, we provide photometry of the sub-subgiant branch star S1063 showing variability on timescales similar to the orbital period, while the ``red straggler'' S1040 shows evidence of an unexplained drop in brightness at phases corresponding to the passage of the white dwarf in front of the giant.Comment: 44 pages, 16 figures, AASTeX, accepted for A

    Photometric variability in the old open cluster M 67. II. General Survey

    Get PDF
    We use differential CCD photometry to search for variability in BVI among 990 stars projected in and around the old open cluster M 67. In a previous paper we reported results for 22 cluster members that are optical counterparts to X-ray sources; this study focuses on the other stars in our observations. A variety of sampling rates were employed, allowing variability on time scales ranging from \sim 0.3 hours to \sim 20 days to be studied. Among the brightest sources studied, detection of variability as small as sigma approx 10 mmag is achieved (with > 3 sigma confidence); for the typical star observed, sensitivity to variability at levels sigma approx 20 mmag is achieved. The study is unbiased for stars with 12.5 < B < 18.5, 12.5 < V < 18.5, and 12 < I < 18 within a radius of about 10 arcmin from the cluster centre. In addition, stars with 10 < BVI < 12.5 were monitored in a few small regions in the cluster. We present photometry for all 990 sources studied, and report the variability characteristics of those stars found to be variable at a statistically significant level. Among the variables, we highlight several sources that merit future study, including stars located on the cluster binary sequence, stars on the giant branch, blue stragglers, and a newly discovered W UMa system.Comment: 12 pages, including 6 figures and 5 tables. Tables 1 and 3 only available in electronic version of paper. Accepted by A&

    Automated electrophysiological and pharmacological evaluation of human pluripotent stem cell-derived cardiomyocytes

    Get PDF
    Automated planar patch clamp systems are widely used in drug evaluation studies because of their ability to provide accurate, reliable, and reproducible data in a high-throughput manner. Typically, CHO and HEK tumorigenic cell lines overexpressing single ion channels are used since they can be harvested as high-density, homogenous, single-cell suspensions. While human pluripotent stem cell-derived cardiomyocytes (hPSC-CMs) are physiologically more relevant, these cells are fragile, have complex culture requirements, are inherently heterogeneous, and are expensive to produce, which has restricted their use on automated patch clamp (APC) devices. Here, we used high efficiency differentiation protocols to produce cardiomyocytes from six different hPSC lines for analysis on the Patchliner (Nanion Technologies GmbH) APC platform. We developed a two-step cell preparation protocol that yielded cell catch rates and whole-cell breakthroughs of ∼80%, with ∼40% of these cells allowing electrical activity to be recorded. The protocol permitted formation of long-lasting (>15 min), high quality seals (>2 GΩ) in both voltage- and current-clamp modes. This enabled density of sodium, calcium, and potassium currents to be evaluated, along with dose–response curves to their respective channel inhibitors, tetrodotoxin, nifedipine, and E-4031. Thus, we show the feasibility of using the Patchliner platform for automated evaluation of the electrophysiology and pharmacology of hPSC-CMs, which will enable considerable increase in throughput for reliable and efficient drug evaluation
    • …
    corecore